5512023_draft_3c.docx




In appendix A, replace "Current" by "Voltage", "Vf = 1.2V" by "If= 100 mA" and ""the Forward Current ... shall not exceed 100 mA" by "the Forward Voltage ... shall not exceed 1.2V"
Justification:
Voltage and Current have been inverted. Method 4011 is a Forward Voltage Test