The following additional changes were discussed & agreed by ESA/PSWG (ref. MoM#109)/Diamond: See attached new spec mark-ups for details of all changes: 3420 Draft 2C & 3420/001 Draft 6D 1) ESCC3420: For new Para. 8.10: for bullet 4, amend to read as follows: • Power applied: Maximum Rated Power (as applicable at Test Temperature) at the Nominal Operating Wavelength as specified in the Detail Specification. For new Para. 8.19: for bullets 4, 5, 6, amend to read as follows: • Test Temperature: Maximum Operating Temperature as specified in the Detail Specification. • Power applied: Maximum Rated Power (as applicable at Test Temperature) at the Nominal Operating Wavelength as specified in the Detail Specification. • Duration: 1000 hours minimum. 2) ESCC3420/001: Para. 2.1.1.1 & 2.1.1.2: editorial changes relevant to Para. 2.3.2 & modified Para. 2.7 Amend test temperature tolerances to be +/-2 degC (Paras. 2.3, 2.4, 2.5, 2.6, 2.7) Paras. 2.6 & 2.7: add nominal wavelength to test conditions (i.e. 1550nm) (plus several editorial changes)
|
|
|