DCR216att.pdf



Replace the proposed wording by the following:

Table 1(b) Maximum Ratings:
Item 1 column 2 : delete d.c.
Item 2 column 2 : delete d.c.
Item 1 column 6 : add remark: "see Figure 1 for derating"
Add an item 5 : Soldering Temperature - Tsol - +260 - °C - Note 1
Add a note 1 : "Duration 10 seconds maximum, the same terminal shall not be resoldered until 3 minutes have elapsed."


Figure 1 : Substitute the figure by the following :(as per original DCR)


Para. 4.2.4 Deviations from Qualification Tests
Add new item (b) as follows and relabel the existing (b) as (c):
"(b) Para. 9.16, Overload: Overload current shall be 2 times rated current."


Para. 4.2.5 Deviations from Lot Acceptance Tests
Add new item (b) as follows and relabel the existing (b) as (c):
"(b) Para. 9.16, Overload: Overload current shall be 2 times rated current."