• Our activities
  • Technologies
  • Other resources
 
 
 













308att.pdf



The following additional changes and corrections are included in this DCR:

A - Table 1(a) Range of Components
The header row of the Table should be equivalent as for the current Variant 01 to 05 ranges (including column numbers & parameter symbols).

B - Figure 2 Physical Dimensions for new Variant 06.
Amend specific limits to be as follows (based on Microspire SESI22WR datasheet & current variant 04 dimensions)(other dimensions A, B, C, are as specified in DCR308):
Dim F: 34.4mm min / 35.3mm max (was: 35.3mm max only)
Dim G: 3.7mm min / 3.9mm max (was: unspecified)
Dim H: 1.9mm min / 2.1mm max (was: 0.45mm max only)
Dim I: 1.3mm min / 1.6mm max (was: 2.1mm max only)
Dim J: 0.2mm min only (was: unspecified)

C - Figure 3
Title is unchanged for this DCR308.

D - Para 4.5.3 Marking of Electrical Characteristics
Amend example of marking to be "4L7M" with tolerance "(+/-20%)"
[was "4L7K" with "(+/-10%)" which is not a valid device]

E - Para 4.5.3.1 Numerical Values
Delete the following obsolete codes from table:
0.0XX; L0XX
0.XX; LXX

F- Para 4.5.3.2 Tolerances
Delete the following obsolete codes from table:
2.0%; G
5.0%; J

Justification:
A & C - For clarification
B - To be consistent with the Microspire datasheet SESI22WR plus existing variants in 3201/009. The proposed dimensions F to J in DCR309 were incorrect.
D, E, & F - To delete obsolete & incorrect references.