The following additional changes are included in this DCR, as incorporated into the attached mark-up specification 4006/014 Issue 5 Draft B:
a) Page 1 Titles & Para 1.1 Scope:
Amend description to reflect the changes in the range (i.e. 2000 to 15000 ohm) and also include the based on type part numbers for the 4 valid variants 08 to 11: "G15K4D489" etc.
b) Table 1(a), Table 1(b) note 3, Figure 2, Para 4.3.2, Para 4.4.2, Para 4.5.2, Table 2:
Delete obsolete variants 01, 02, 03, 04, 05, 06 from the table and all references throughout the specification.
c) Table 1(a):
Change in column 3: "NOM" to read "RZ"
d) Table 1(a), Table 1(b), Figure 2, Para 4.3.2, Table 5, Table 6:
Remove any irrelevant trailing zeros from values & limits throughout the specification (e.g. "10.00%" becomes "10%")
e) Table 2, Table 6
Change symbol "Ri" to be "RI"
f) Appendix A for Betatherm
All deviations applicable to variant 08 (to testing level B) shall also apply to Variants 09, 10, 11
---------------
Justification
a), c), d), e), Editorial changes for the purposes of consistency and clarification.
b) Betatherm have confirmed that variants 01 to 06 are obsolete and are no longer supported for procurement (Variants 08 to 11 are supported). Accordingly without any manufacturer support they should be removed from the specification.
f) Betatherm has a single process using the same materials that is applicable to all variants 08 to 11; hence the deviations already approved for Variant 08 (ref. DCR119 & 181) should also be applied to the new variants 09, 10, 11.
|