1. Change #1 :
This change is deleted and replaced by the following:

Amend Top in Para 1.5, Max Rating table in 9202/076, to state:

// Minimum Guaranteed Operating Temperature Range // Top // -55 to +125 oC // Tamb , Note 4 //

And add new note 4 to the table:

4. For an individual ASIC design see ASIC Sheet for the actual maximum operating temperature range.

........................